Fixed detectors
Fixed gas detectors are represented by multiple series of devices.
Flammable gases such as natural gas, LPG, solvent vapors and other flammable substances can be detected in a standard environment using a two-stage GC20P detector or a three-stage GI30W detector. Detector GC20P could be ordered also for 230 V / 50 Hz power supply as GC20P-230V or as GC20P-FGD which also allows the connection of an external detector and includes a siren and a voltage source for the emergency valve. GSC4 is a sensor for flammable gases with 4-20 mA current loop output.
In places with Zone 2 explosive atmosphere you can use GR31 detectors.
A three-stage GIC40 detector, two-stage GICO20-230V for 230 V / 50 Hz power supply, GICO20P-FGD, which also allows the connection of an external detector and includes a siren and a voltage source for the emergency valve, and 4-20 mA current loop sensor GSU2 are intended for detection of carbon monoxide (CO) in the atmosphere.
A carbon dioxide (CO2) could be detected by two-stage detector GIR80 or sensor GSR8 with 4-20 mA current loop output and 0-10 V voltage output.
A special category is represented by a refrigerant detector GC20R that responds to the filling of the cooling devices based on R134A and GC20RF-230V for 230V / 50 Hz power supply.
Portable devices
For service and inspection workers, we produce general-purpose detector GD550, a device that allows using interchangeable probes to measure and detect more variables, so that in one practical plastic case, the customer can create a setup according to their own needs. The basic options include: detection of flammable gases and carbon monoxide in the air, measuring pressure and temperature. GD550 can be also suplemented with a sensor for measuring low air pressure (4 Pa test) or with a simple flue gas analyzer.
For boiler room operators or when occasional checks are required, we can offer a simple single-purpose GOFL instrument for detecting combustible gases or a GOCO instrument for detecting carbon monoxide. We also currently offer the older GD52 and GDCO types of single purpose portable instruments.
We also offer the GOOX single-purpose detector for monitoring carbon dioxide (CO2) concentrations in indoor environments such as offices and classrooms.
Auxiliary components
Fixed detectors can be used separately as input devices connected to the control system. If the detection system is to function independently, the detectors are usually suplemented with the power supply NZ22, NZ44, NZ34, NZ425, alarm control panel FZ28 or even sirens and beacons.